Single Splits – RAC Wall Mounted / SRK71ZR-S / SRC71ZR-S

Category:

Description

SRK71ZR-S

Wall Mounted – Indoor Unit

SRK71ZR-S / SRC71ZR-S

Wall-mounted RAC indoor unit with a nominal cooling capacity of 7.1 kW.

Technical Specifications


Data Sheet (Printer Friendly)

 

General Data
Nominal cooling capacity (min-max) kW 7.1 (2.3 – 7.7)
Nominal heating capacity (min-max) kW 8.0 (2.0 – 10.0)
Exterior Dimensions (H x W x D) mm Unit:339 x 1197 x 262
Net Weight kg 15.5
Air Flow Cooling (Hi/Me/Lo) m3/min 20.5 / 18.6 / 16.2 / 10.4
Air Flow Heating (Hi/Me/Lo) m3/min 25.5 / 19.8 / 17.3 / 13.3
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 44 / 41 / 37 / 25
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 46 / 39 / 35 / 28


Schematics



Wall Mounted – Outdoor Unit

SRC71ZR-S
RAC outdoor unit with a nominal cooling capacity of 7.1 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 7.1 (2.3 – 7.7)
Nominal heating capacity (min-max) kW 8.0 (2.0 – 10.0)
EER (Energy Label) 3.46
COP (Energy Label) 3.88
Exterior Dimensions (H x W x D) mm 750 x 880(+88) x 340
Net Weight kg 57
Sound Pressure Level (Cooling/Heating) dB(A) 53/51
Energy class (Cooling/Heating) A++/A++
SEER “Average climate”/(Energy label) 7.20
SCOP “Average climate”/(Energy label) 4.50

 

 

Electrical Data
Pdesignc kW 7.10
Pdesignh (@-10°C) kW 6.60
Annual electricity consumption (Cooling/Heating) kWh/a 346/2055
Power Source 1Phase, 220 – 240V, 50Hz
Inrush current (220/230/240v) A 9.6 / 9.1 / 8.8
Max. running current A 17
Power consumption (Cooling/Heating) kW 2.05 / 2.06

 

Installation
Refrigerant (GWP) R410A (2088)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 15.88 (5/8″)
Ref. Max Piping Length m Max. 30
Vertical Height differences / Outdoor is higher/lower m Max. 20 / Max. 20

Schematics