Single Splits – RAC Wall Mounted / SRK63ZR-S / SRC63ZR-S

Category:

Description

SRK63ZR-S

Wall Mounted – Indoor Unit

SRK63ZR-S / SRC63ZR-S

Wall-mounted RAC indoor unit with a nominal cooling capacity of 6.3 kW.

Technical Specifications


Data Sheet (Printer Friendly)

 

General Data
Nominal cooling capacity (min-max) kW 6.3 (1.2 - 7.1)
Nominal heating capacity (min-max) kW 7.1 (0.8 - 9.0)
Exterior Dimensions (H x W x D) mm Unit:339 x 1197 x 262
Net Weight kg 15.5
Air Flow Cooling (Hi/Me/Lo) m3/min 20.5 / 18.1 / 15.7 / 10.4
Air Flow Heating (Hi/Me/Lo) m3/min 23.5 / 19.0 / 16.5 / 13.1
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 44 / 39 / 35 / 25
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 44 / 38 / 34 / 28


Schematics



Wall Mounted - Outdoor Unit

SRC63ZR-S
RAC outdoor unit with a nominal cooling capacity of 6.3 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 6.3 (1.2 - 7.1)
Nominal heating capacity (min-max) kW 7.1 (0.8 - 9.0)
EER (Energy Label) - 3.41
COP (Energy Label) - 4.08
Exterior Dimensions (H x W x D) mm 640 x 800(+71) x 290
Net Weight kg 45
Sound Pressure Level (Cooling/Heating) dB(A) 54/54
Energy class (Cooling/Heating) -- A++/A++
SEER "Average climate"/(Energy label) -- 7.60
SCOP "Average climate"/(Energy label) -- 4.70

 

 

Electrical Data
Pdesignc kW 6.30
Pdesignh (@-10°C) kW 5.40
Annual electricity consumption (Cooling/Heating) kWh/a 291/1610
Power Source - 1Phase, 220 - 240V, 50Hz
Inrush current (220/230/240v) A 8.5 / 8.1 / 7.8
Max. running current A 14.5
Power consumption (Cooling/Heating) kW 1.85 / 1.74

 

Installation
Refrigerant (GWP) - R410A (2088)
Designated heating season - Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4") / 12.7 (1/2")
Ref. Max Piping Length m Max. 30
Vertical Height differences / Outdoor is higher/lower m Max. 20 / Max. 20

Schematics