Specifications

[:en]

Specifications

For product information for our Hydrolution range, please see the table below or download our specifications page.

3HP 3.5HP 6HP
Indoor unit HMA100V1
HMA100V2
HMA100VM1 HMA100V1
HMA100V2
HMA100VM1 HMS140VA1
HMS140VA2
Outdoor unit FDCW71VNX-A FDCW100VNX-A FDCW140VNX-A
Power source 1 phase 230V 50Hz
3 phase 400V 50Hz
3 phase 230V 50Hz 1 phase 230V 50Hz
3 phase 400V 50Hz
3 phase 230V 50H 1 phase 230V 50Hz
3 phase 400V 50Hz
Heating
Nominal Capacity
condition 1 kW 8.0 (3.0 – 8.0) 9.0 (3.5 – 12.0) 16.5 (5.8 – 16.5)
condition 2 kW 8.3 (2.0 – 8.3) 9.2 (3.5 – 10.5) 16.5 (4.2 – 17.2)
COP condition 1 3.33 3.60 3.31
condition 2 4.09 4.28 4.20
Cooling
Nominal Capacity
condition 1 kW 7.1 (2.0 – 7.1) 8.0 (3.0 – 9.0) 11.8 (3.1 – 11.8)
condition 2 kW 10.7 (2.7 – 10.7) 11.0 (3.3 – 12.0) 16.5 (5.2 – 16.5)
EER condition 1 2.68 2.81 2.65
condition 2 3.35 3.62 3.78
Tapping capacity 12liter/min liter 270 270
16liter/min liter 200 200
Operation range
(Ambient temperature)
heating -20-43
cooling 15-43
Operation range
(Water temperature)
heating 25-58 (65 with immersion heater)
cooling 7-25 18-25
Max refrigerant
pipe length
m 30
Max height difference
m 7
Indoor Unit Height mm 1760 (+20-50mm, adjustable feet) 1004
Width mm 600 513
Depth mm 650 360
Weight (without water in the system) kg 140 60
Immersion heater 9kW 4steps
Volume total liter 270 ±5%
Volume hot water coil liter 14
Volume expansion vessel liter 18
Dimensions, climate system pipe mm 22 28
Dimensions, hot water pipe mm 22
Water pipe connections Compression fittings
Outdoor Unit Height mm 750 845 1300
Width mm 880 (+88 with valve cover) 970 970
Depth mm 340 370 (+80 with foot rail) 370 (+80 with foot rail)
Weight kg 60 81 105
Sound Power level dB(A) 64 64.5 71
Sound Power level (Silent mode) dB(A) 61 62 68
Sound Pressure level dB(A) 48 50 54
Sound Pressure level (Silent mode) dB(A) 45 47 51
Airflow m3 /min 50 73 100
Drain pan heater W 100 120 120
Type of compressor Rotary
Ref control EEV
Refrigerant volume (pipe length without additional charge) kg (m) 2.55 (15) 2.9 (15) 4.0 (15)
Dimensions, refrigerant pipe mm (inches) Gas pipe: OD 15.88 (5/8″), Liquid pipe: OD 9.52 (3/8″)
Ref pipe connections Flare

[:]