Description
SRK25ZMP-S
Wall Mounted – Indoor Unit
SRK25ZMP-S / SRC25ZMP-S
Wall-mounted RAC indoor unit with a nominal cooling capacity of 2.5 kW.
Technical Specifications
Data Sheet (Printer Friendly)
Nominal cooling capacity (min-max) | kW | 2.5 (0.9 – 2.8) |
Nominal heating capacity (min-max) | kW | 2.8 (0.8 – 3.9) |
Exterior Dimensions (H x W x D) | mm | Unit:262 x 769 x 210 |
Net Weight | kg | 6.9 |
Air Flow Cooling (Hi/Me/Lo) | m3/min | 10.1 / 7.3 / 4.2 |
Air Flow Heating (Hi/Me/Lo) | m3/min | 9.5 / 7.3 / 5.2 |
Sound Pressure Level Cooling (Hi/Me/Lo) | dB(A) | 45 / 34 / 23 |
Sound Pressure Level Heating (Hi/Me/Lo) | dB(A) | 43 / 34 / 26 |
Schematics
Wall Mounted – Outdoor Unit
SRC25ZMP-S
RAC outdoor unit with a nominal cooling capacity of 2.5 kW.
Technical Specifications
Nominal cooling capacity (min-max) | kW | 2.5 (0.9 – 2.8) |
Nominal heating capacity (min-max) | kW | 2.8 (0.8 – 3.9) |
EER (Energy Label) | – | 3.21 |
COP (Energy Label) | – | 3.71 |
Exterior Dimensions (H x W x D) | mm | 540 x 645(+57) x 275 |
Net Weight | kg | 25 |
Sound Pressure Level (Cooling/Heating) | dB(A) | 47/45 |
Energy class (Cooling/Heating) | — | A/A |
SEER “Average climate”/(Energy label) | — | 5.50 |
SCOP “Average climate”/(Energy label) | — | 3.82 |
Pdesignc | kW | 2.50 |
Pdesignh (@-10°C) | kW | 2.80 |
Annual electricity consumption (Cooling/Heating) | kWh/a | 160/1027 |
Power Source | – | 1Phase, 220 – 240V, 50Hz |
Inrush current (220/230/240v) | A | 3.9 / 3.8 / 3.6 |
Max. running current | A | 9 |
Power consumption (Cooling/Heating) | kW | 0.78 / 0.755 |
Refrigerant (GWP) | – | R410A (2088) |
Designated heating season | – | Average |
Ref. Piping Size (Liquid/Gas) | Ø mm | 6.35 (1/4″) / 9.52 (3/8″) |
Ref. Max Piping Length | m | Max. 15 |
Vertical Height differences / Outdoor is higher/lower | m | Max. 10 / Max. 10 |