Single Splits – RAC Floor Standing / SRF50ZMX-S / SRC50ZMX-S

Category:

Description

SRF50ZMX-S

Floor Standing – Indoor Unit

SRF50ZMX-S / SRC50ZMX-S

Floor standing RAC indoor unit with a nominal cooling capacity of 5.0 kW.

Technical Specifications


Data Sheet (Printer Friendly)

 

General Data
Nominal cooling capacity (min-max) kW 5.0 (1.1 – 5.2)
Nominal heating capacity (min-max) kW 6.0 (0.6 – 6.9)
Exterior Dimensions (H x W x D) mm Unit:600 x 860 x 238
Net Weight kg 19
Air Flow Cooling (Hi/Me/Lo) m3/min 11.5 / 9.6 / 7.4 / 6.6
Air Flow Heating (Hi/Me/Lo) m3/min 12.0 / 10.0 / 9.4 / 7.6
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 46 / 42 / 35 / 32
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 47 / 41 / 39 / 33


Schematics



Floor Standing – Outdoor Unit

SRC50ZMX-S

RAC outdoor unit with a nominal cooling capacity of 5.0 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 5.0 (1.1 – 5.2)
Nominal heating capacity (min-max) kW 6.0 (0.6 – 6.9)
EER (Energy Label) 3.60
COP (Energy Label) 3.90
Exterior Dimensions (H x W x D) mm 640 x 800(+71) x 290
Net Weight kg 38
Sound Pressure Level (Cooling/Heating) dB(A) 50/50
Energy class (Cooling/Heating) A+/A+
SEER “Average climate”/(Energy label) 6.01
SCOP “Average climate”/(Energy label) 4.19

 

 

Electrical Data
Pdesignc kW 5.00
Pdesignh (@-10°C) kW 5.20
Annual electricity consumption (Cooling/Heating) kWh/a 292/1736
Power Source 1Phase, 220 – 240V, 50Hz
Inrush current (220/230/240v) A 7.1 / 6.8 / 6.5
Max. running current A 15
Power consumption (Cooling/Heating) kW 1.390 / 1.540

 

Installation
Refrigerant (GWP) R410A (2088)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 12.7 (1/2″)
Ref. Max Piping Length m Max. 30
Vertical Height differences / Outdoor is higher/lower m Max. 20 / Max. 20

Schematics