Single Splits – RAC Ceiling Concealed / SRR25ZM-S / SRC25ZMX-S

Category:

Description

SRF50ZMX-S

Ceiling Concealed – Indoor Unit

SRR25ZM-S / SRC25ZMX-S

Ceiling concelaed RAC indoor unit with a nominal cooling capapcity of 2.5 kW.

Technical Specifications


Data Sheet (Printer Friendly)

 

General Data
Nominal cooling capacity (min-max) kW 2.5 (1.0 – 3.3)
Nominal heating capacity (min-max) kW 3.4 (1.4 – 4.8)
Exterior Dimensions (H x W x D) mm Unit:200 x 750 x 500
Net Weight kg 20.5
Air Flow Cooling (Hi/Me/Lo) m3/min 9.5 / 8.0 / 6.5 / 4.5
Air Flow Heating (Hi/Me/Lo) m3/min 10.0 / 9.0 / 8.0 / 6.0
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 37 / 33 / 30 / 24
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 40 / 37 / 34 /28


Schematics



Ceiling Concealed – Outdoor Unit

SRC25ZMX-S

RAC outdoor unit with a nominal cooling capacity of 2.5 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 2.5 (1.0 – 3.3)
Nominal heating capacity (min-max) kW 3.4 (1.4 -4.8)
EER (Energy Label) 4.39
COP (Energy Label) 4.53
Exterior Dimensions (H x W x D) mm 595 x 780(+62) x 290
Net Weight kg 35
Sound Pressure Level (Cooling/Heating) dB(A) 47/47
Energy class (Cooling/Heating) A++/A
SEER “Average climate”/(Energy label) 6.43
SCOP “Average climate”/(Energy label) 4.08

 

 

Electrical Data
Pdesignc kW 2.50
Pdesignh (@-10°C) kW 3.30
Annual electricity consumption (Cooling/Heating) kWh/a 136 / 1133
Power Source 1Phase, 220 – 240V, 50Hz
Inrush current (220/230/240v) A 3.9 / 3.7 / 3.6
Max. running current A 0
Power consumption (Cooling/Heating) kW 0.57 / 0.75

 

Installation
Refrigerant (GWP) R410A (2088)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 9.52 (3/8″)
Ref. Max Piping Length m Max. 15
Vertical Height differences / Outdoor is higher/lower m Max. 10 / Max. 10

Schematics