Description
SRR35ZM-S
Ceiling Concealed – Indoor Unit
SRR35ZM-S / SRC35ZMX-S
Ceiling concelaed RAC indoor unit with a nominal cooling capapcity of 2.5 kW.
Technical Specifications
Data Sheet (Printer Friendly)
Nominal cooling capacity (min-max) | kW | 3.5 (1.0 – 3.9) |
Nominal heating capacity (min-max) | kW | 4.2 (1.5 – 5.2) |
Exterior Dimensions (H x W x D) | mm | Unit:200 x 750 x 500 |
Net Weight | kg | 20.5 |
Air Flow Cooling (Hi/Me/Lo) | m3/min | 10.0 / 8.5 / 7.0 / 5.0 |
Air Flow Heating (Hi/Me/Lo) | m3/min | 10.5 / 9.5 / 8.5 / 6.5 |
Sound Pressure Level Cooling (Hi/Me/Lo) | dB(A) | 38 / 34 / 31 / 25 |
Sound Pressure Level Heating (Hi/Me/Lo) | dB(A) | 41 / 38 / 35 /29 |
Schematics
Ceiling Concealed – Outdoor Unit
SRC35ZMX-S
RAC outdoor unit with a nominal cooling capacity of 3.5 kW.
Technical Specifications
Nominal cooling capacity (min-max) | kW | 3.5 (1.0 -3.9) |
Nominal heating capacity (min-max) | kW | 4.2 (1.5 -5.2) |
EER (Energy Label) | – | 3.57 |
COP (Energy Label) | – | 4.08 |
Exterior Dimensions (H x W x D) | mm | 595 x 780(+62) x 290 |
Net Weight | kg | 35 |
Sound Pressure Level (Cooling/Heating) | dB(A) | 50/50 |
Energy class (Cooling/Heating) | — | A++/A+ |
SEER “Average climate”/(Energy label) | — | 6.31 |
SCOP “Average climate”/(Energy label) | — | 4.02 |
Pdesignc | kW | 3.50 |
Pdesignh (@-10°C) | kW | 3.55 |
Annual electricity consumption (Cooling/Heating) | kWh/a | 195 / 1238 |
Power Source | – | 1Phase, 220 – 240V, 50Hz |
Inrush current (220/230/240v) | A | 5.0 / 4.8 / 4.6 |
Max. running current | A | 8 |
Power consumption (Cooling/Heating) | kW | 0.98 / 1.03 |
Refrigerant (GWP) | – | R410A (2088) |
Designated heating season | – | Average |
Ref. Piping Size (Liquid/Gas) | Ø mm | 6.35 (1/4″) / 9.52 (3/8″) |
Ref. Max Piping Length | m | Max. 15 |
Vertical Height differences / Outdoor is higher/lower | m | Max. 10 / Max. 10 |