FDE100VG

Ceiling Suspended – Indoor Unit

FDE100VSVG

Ceiling suspended PAC indoor unit with a nominal cooling capacity of 10.0 kW.

Technical Specifications


Data Sheet (Printer Friendly)

 

General Data
Nominal cooling capacity (min-max) kW 10.0 (4.0 – 11.2)
Nominal heating capacity (min-max) kW 11.2 (4.0 – 12.5)
Exterior Dimensions (H x W x D) mm Unit:250 x 1620 x 690
Net Weight kg 43
Air Flow Cooling (Hi/Me/Lo) m3/min 32 / 26 / 21 / 16.5
Air Flow Heating (Hi/Me/Lo) m3/min 32 / 26 / 21 / 16.5
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 48 / 43 / 38 / 34
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 48 / 43 / 38 / 34

 

Schematics



Ceiling Suspended – Outdoor Unit

FDC100VS

PAC outdoor unit with a nominal cooling capacity of 10.0 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 10.0 (4.0 – 11.2)
Nominal heating capacity (min-max) kW 11.2 (4.0 – 12.5)
EER (Energy Label) 3.51
COP (Energy Label) 3.86
Exterior Dimensions (H x W x D) mm 845 x 970 x 370
Net Weight kg 83
Sound Pressure Level (Cooling/Heating) dB(A) 49/49
Energy class (Cooling/Heating) A/A
SEER “Average climate”/(Energy label) 5.39
SCOP “Average climate”/(Energy label) 3.90

 

 

Electrical Data
Pdesignc kW 10.0
Pdesignh (@-10°C) kW 7.90
Annual electricity consumption (Cooling/Heating) kWh/a 649/2833
Power Source 3 Phase 380-415V 50Hz, 3 Phase 380V 60Hz
Inrush current (220/230/240v) A 5
Max. running current A 15
Power consumption (Cooling/Heating) kW 2.85 / 2.90

 

Installation
Refrigerant (GWP) R410A (2088)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 9.52 (3/8″) / 15.88 (5/8″)
Ref. Max Piping Length m Max. 50
Vertical Height differences / Outdoor is higher/lower m Max. 30 / Max. 15

Schematics