Single Splits – PAC Ceiling Cassette / FDT40ZMXVF

Category:

Description

FDT40VF

Ceiling Cassette – Indoor Unit

FDT40ZMXVF

Ceiling cassette PAC indoor unit with a nominal cooling capacity of 4.0 kW.

Technical Specifications


 

General Data
Nominal cooling capacity (min-max) kW 4.0 (1.1 – 4.7)
Nominal heating capacity (min-max) kW 4.5 (0.6 – 5.4)
Exterior Dimensions (H x W x D) mm Unit: 246 x 840 x 840; Panel: 35 x 950 x 950
Net Weight kg 27.5 (Unit: 22; Panel: 5.5)
Air Flow Cooling (Hi/Me/Lo) m3/min 20/ 18 / 16 / 14
Air Flow Heating (Hi/Me/Lo) m3/min 20/ 18 / 16 / 14
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 39/ 33 / 31 / 30
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 39/ 33 / 31 / 30

 

Schematics



Ceiling cassette – Outdoor Unit

SRC40ZMX-S

PAC outdoor unit with a nominal cooling capacity of 4.0 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 4.0 (1.1 – 4.7)
Nominal heating capacity (min-max) kW 4.5 (0.6 – 5.4)
EER (Energy Label) 4.30
COP (Energy Label) 4.25
Exterior Dimensions (H x W x D) mm 640 x 800 (+71) x 290
Net Weight kg 45
Sound Pressure Level (Cooling/Heating) dB(A) 50/50
Energy class (Cooling/Heating) A++/A+
SEER “Average climate”/(Energy label) 7.57
SCOP “Average climate”/(Energy label) 4.16

 

 

Electrical Data
Pdesignc kW 4.0
Pdesignh (@-10°C) kW 4.8
Annual electricity consumption (Cooling/Heating) kWh/a 186 / 1617
Power Source 1 Phase 220-240V 50Hz, 1 Phase 220V 60Hz
Inrush current (220/230/240v) A 5
Max. running current A 12
Power consumption (Cooling/Heating) kW 0.93 / 1.06

 

Installation
Refrigerant (GWP) R410A (2088)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 12.7 (1/2″)
Ref. Max Piping Length m Max. 30
Vertical Height differences / Outdoor is higher/lower m Max. 20 / Max. 20

Schematics