Multi Splits – PAC Wall Mounted / SRK200VSAPZR

Category:

Description

SRK100ZR-S X2

Compact Ceiling Cassette – Indoor Unit

SRK200VSAPZR

Wall-mounted PAC indoor unit with a nominal cooling capacity of 10.0 kW.

Technical Specifications


 

General Data
Nominal cooling capacity (min-max) kW 19.0 ( 5.2- 22.4 )
Nominal heating capacity (min-max) kW 22.4 (3.3- 25.0)
Exterior Dimensions (H x W x D) mm Unit:339 x 1197 x 262
Net Weight kg 16.5
Air Flow Cooling (Hi/Me/Lo) m3/min 24.5 / 21.3 / 17.6 / 10.4
Air Flow Heating (Hi/Me/Lo) m3/min 27.5 / 23.2 / 19.1 / 13.6
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 48 / 45 / 40 / 27
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 48 / 43 / 38 / 30

 

Schematics



Compact Ceiling cassette – Outdoor Unit

FDC200VSA

PAC outdoor unit with a nominal cooling capacity of 20.0 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 19.0 (5.2 – 22.4)
Nominal heating capacity (min-max) kW 22.4 (3.3- 25.0)
EER (Energy Label) 3.53
COP (Energy Label) 3.02
Exterior Dimensions (H x W x D) mm 1300 x 970 x 370
Net Weight kg 115
Sound Pressure Level (Cooling/Heating) dB(A) 58/59

 

 

Electrical Data
Power Source 3 Phase 380-415V, 50Hz, 3 Phase 380V 60Hz
Inrush current (220/230/240v) A 5
Max. running current A 20
Power consumption (Cooling/Heating) kW 7.52 / 7.41

 

Installation
Ref. Piping Size (Liquid/Gas) Ø mm 9.52 (3/8″) / 22.22 (7/8″)
Ref. Max Piping Length m Max. 70
Vertical Height differences / Outdoor is higher/lower m Max. 30 / Max. 15

Schematics