Single Splits – RAC Wall Mounted / SRK/SRC35ZS-ST

Category:

Description

SRK/SRC35ZS-ST

Wall Mounted – Indoor Unit

SRK/SRC35ZS-ST

Wall-mounted RAC indoor unit with a nominal cooling capacity of 2.0 kW.

Technical Specifications


 

General Data
Nominal cooling capacity (min-max) kW 2.0 (1.0 – 2.8)
Nominal heating capacity (min-max) kW 2.7 (0.9 – 4.2)
Exterior Dimensions (H x W x D) mm Unit:290 x 870 x 230
Net Weight kg 9.5
Air Flow Cooling (Hi/Me/Lo) m3/min 9.3 / 7.0 / 5.9 / 5.0
Air Flow Heating (Hi/Me/Lo) m3/min 10.0 / 8.5 / 6.5 / 5.9
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 34 / 25 /22 / 19
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 36 / 29 / 23 / 19


Schematics



Wall Mounted – Outdoor Unit

SRC20ZS-S
RAC outdoor unit with a nominal cooling capacity of 2.0 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 2.0(1.0 – 2.8)
Nominal heating capacity (min-max) kW 2.7(0.9 – 4.2)
EER (Energy Label) 4.55
COP (Energy Label) 4.35
Exterior Dimensions (H x W x D) mm 540 x 780 (+62) x 290
Net Weight kg 31.5
Sound Pressure Level (Cooling/Heating) dB(A) 45/45
Energy class (Cooling/Heating) A++/A++
SEER “Average climate”/(Energy label) 7.80
SCOP “Average climate”/(Energy label) 4.60

 

 

Electrical Data
Pdesignc kW 2.0
Pdesignh (@-10°C) kW 2.40
Annual electricity consumption (Cooling/Heating) kWh/a 90 / 732
Power Source 1Phase, 220 – 240V, 50Hz
Inrush current (220/230/240v) A 3.2 / 3.1 / 3.0
Max. running current A 9
Power consumption (Cooling/Heating) kW 0.44 / 0.62

 

Installation
Refrigerant (GWP) R410A (2088)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 9.52 (3/8″)
Ref. Max Piping Length m Max. 20
Vertical Height differences / Outdoor is higher/lower m Max. 10 / Max. 10

Schematics