Single Splits – RAC Wall Mounted /SRC50ZS-S

Category:

Description

SRK25ZS-S

Wall Mounted – Indoor Unit

SRK25ZS-S / SRC25ZS-S

Wall-mounted RAC indoor unit with a nominal cooling capacity of 2.5 kW.

Technical Specifications


Data Sheet (Printer Friendly)

 

General Data
Nominal cooling capacity (min-max) kW 2.5 (1.0 – 3.0)
Nominal heating capacity (min-max) kW 3.2 (0.9 – 4.4)
Exterior Dimensions (H x W x D) mm Unit:290 x 870 x 230
Net Weight kg 9.5
Air Flow Cooling (Hi/Me/Lo) m3/min 9.9 / 8.0 / 5.9 / 5.0
Air Flow Heating (Hi/Me/Lo) m3/min 11.3 / 8.7 / 6.7 / 5.9
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 36 / 28 / 23 / 19
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 39 / 30 / 24 / 19


Schematics



Wall Mounted – Outdoor Unit

SRC25ZS-S
RAC outdoor unit with a nominal cooling capacity of 2.5 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 2.5 (1.0 – 3.0)
Nominal heating capacity (min-max) kW 3.2 (0.9 – 4.4)
EER (Energy Label) 4.03
COP (Energy Label) 4.00
Exterior Dimensions (H x W x D) mm 540 x 780 (+62) x 290
Net Weight kg 31.5
Sound Pressure Level (Cooling/Heating) dB(A) 46/46
Energy class (Cooling/Heating) A++/A++
SEER “Average climate”/(Energy label) 7.80
SCOP “Average climate”/(Energy label) 4.60

 

 

Electrical Data
Pdesignc kW 2.50
Pdesignh (@-10°C) kW 2.50
Annual electricity consumption (Cooling/Heating) kWh/a 113 / 762
Power Source 1Phase, 220 – 240V, 50Hz
Inrush current (220/230/240v) A 4.0 / 3.8 / 3.6
Max. running current A 9
Power consumption (Cooling/Heating) kW 0.62 / 0.80

 

Installation
Refrigerant (GWP) R410A (2088)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 9.52 (3/8″)
Ref. Max Piping Length m Max. 20
Vertical Height differences / Outdoor is higher/lower m Max. 10 / Max. 10

Schematics