Single Splits – PAC Low Static Pressure Duct Connected / FDUM71VNXVF1

Description

FDUM71VF1

Low Static Pressure Duct Connected – Indoor Unit

FDUM71VNXVF1

Low static pressure duct connected PAC indoor unit with a nominal cooling capacity of 7.1 kW.

Technical Specifications


 

General Data
Nominal cooling capacity (min-max) kW 7.1 (3.2 – 8.0)
Nominal heating capacity (min-max) kW 8.0 (3.6 – 9.0)
Exterior Dimensions (H x W x D) mm Unit:280 x 950 x 635
Net Weight kg 34
Air Flow Cooling (Hi/Me/Lo) m3/min 24/ 19 / 15 / 10
Air Flow Heating (Hi/Me/Lo) m3/min 24/ 19 / 15 / 10
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 38/ 33 / 29 / 25
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 38/ 33 / 29 / 25

 

Schematics



Low Static Pressure Duct Connected – Outdoor Unit

FDC71VNX
PAC outdoor unit with a nominal cooling capacity of 7.1 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 7.1 (3.2 – 8.0)
Nominal heating capacity (min-max) kW 8.0 (3.6 – 9.0)
EER (Energy Label) 3.50
COP (Energy Label) 4.02
Exterior Dimensions (H x W x D) mm 750 x 880 (+88) x 340
Net Weight kg 60
Sound Pressure Level (Cooling/Heating) dB(A) 51/48
Energy class (Cooling/Heating) A/A
SEER “Average climate”/(Energy label) 5.24
SCOP “Average climate”/(Energy label) 3.90

 

 

Electrical Data
Pdesignc kW 7.1
Pdesignh (@-10°C) kW 7.0
Annual electricity consumption (Cooling/Heating) kWh/a 475 / 2513
Power Source 1 Phase 220-240V 50Hz, 1 Phase 220V 60Hz
Inrush current (220/230/240v) A 5
Max. running current A 17
Power consumption (Cooling/Heating) kW 2.03 / 1.99

 

Installation
Refrigerant (GWP) R410A (2088)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 9.52 (3/8″) / 15.88 (5/8″)
Ref. Max Piping Length m Max. 50
Vertical Height differences / Outdoor is higher/lower m Max. 30 / Max. 15

Schematics