Single Splits – PAC Compact Ceiling Cassette / FDTC60ZMXVF

Description

[:en]

FDTC60VF

Compact Ceiling Cassette – Indoor Unit

FDTC60ZMXVF

Ceiling cassette PAC indoor unit with a nominal cooling capacity of 6.0 kW.

Technical Specifications


Data Sheet (Printer Friendly)

 

General Data
Nominal cooling capacity (min-max) kW 5.6 (1.1 – 6.3)
Nominal heating capacity (min-max) kW 6.7 (0.6 – 6.7)
Exterior Dimensions (H x W x D) mm Unit: 248 x 570 x 570; Panel: 35 x 700 x 700
Net Weight kg 18.5 (Unit: 15; Panel: 3.5)
Air Flow Cooling (Hi/Me/Lo) m3/min 13. 5/ 13.5 / 10 / 7
Air Flow Heating (Hi/Me/Lo) m3/min 13. 5/ 13.5 / 10 / 8
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 47 / 46 / 39 / 30
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 47 / 46 / 39 / 32

 

Schematics



Compact Ceiling cassette – Outdoor Unit

SRC60ZMX-S
PAC outdoor unit with a nominal cooling capacity of 6.0 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 5.6 (1.1 – 6.3)
Nominal heating capacity (min-max) kW 6.7 (0.6 – 6.7)
EER (Energy Label) 2.81
COP (Energy Label) 3.24
Exterior Dimensions (H x W x D) mm 640 x 800 (+71) x 290
Net Weight kg 45
Sound Pressure Level (Cooling/Heating) dB(A) 54/54
Energy class (Cooling/Heating) A+/A
SEER “Average climate”/(Energy label) 5.76
SCOP “Average climate”/(Energy label) 3.80

 

 

Electrical Data
Pdesignc kW 5.6
Pdesignh (@-10°C) kW 5.9
Annual electricity consumption (Cooling/Heating) kWh/a 341 / 2172
Power Source 1 Phase 220-240V 50Hz, 1 Phase 220V 60Hz
Inrush current (220/230/240v) A 5
Max. running current A 15
Power consumption (Cooling/Heating) kW 1.99 / 2.07

 

Installation
Refrigerant (GWP) R410A (2088)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 12.7 (1/2″)
Ref. Max Piping Length m Max. 30
Vertical Height differences / Outdoor is higher/lower m Max. 20 / Max. 20

Schematics


[:el]

FDTC60VF

Compact Ceiling Cassette – Indoor Unit

FDTC60ZMXVF

Ceiling cassette PAC indoor unit with a nominal cooling capacity of 6.0 kW.

Technical Specifications


 

General Data
Nominal cooling capacity (min-max) kW 5.6 (1.1 – 6.3)
Nominal heating capacity (min-max) kW 6.7 (0.6 – 6.7)
Exterior Dimensions (H x W x D) mm Unit: 248 x 570 x 570; Panel: 35 x 700 x 700
Net Weight kg 18.5 (Unit: 15; Panel: 3.5)
Air Flow Cooling (Hi/Me/Lo) m3/min 13. 5/ 13.5 / 10 / 7
Air Flow Heating (Hi/Me/Lo) m3/min 13. 5/ 13.5 / 10 / 8
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 47 / 46 / 39 / 30
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 47 / 46 / 39 / 32

 

Schematics



Compact Ceiling cassette – Outdoor Unit

SRC60ZMX-S
PAC outdoor unit with a nominal cooling capacity of 6.0 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 5.6 (1.1 – 6.3)
Nominal heating capacity (min-max) kW 6.7 (0.6 – 6.7)
EER (Energy Label) 2.81
COP (Energy Label) 3.24
Exterior Dimensions (H x W x D) mm 640 x 800 (+71) x 290
Net Weight kg 45
Sound Pressure Level (Cooling/Heating) dB(A) 54/54
Energy class (Cooling/Heating) A+/A
SEER “Average climate”/(Energy label) 5.76
SCOP “Average climate”/(Energy label) 3.80

 

 

Electrical Data
Pdesignc kW 5.6
Pdesignh (@-10°C) kW 5.9
Annual electricity consumption (Cooling/Heating) kWh/a 341 / 2172
Power Source 1 Phase 220-240V 50Hz, 1 Phase 220V 60Hz
Inrush current (220/230/240v) A 5
Max. running current A 15
Power consumption (Cooling/Heating) kW 1.99 / 2.07

 

Installation
Refrigerant (GWP) R410A (2088)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 12.7 (1/2″)
Ref. Max Piping Length m Max. 30
Vertical Height differences / Outdoor is higher/lower m Max. 20 / Max. 20

Schematics


[:ru]

FDTC60VF

Compact Ceiling Cassette – Indoor Unit

FDTC60ZMXVF

Ceiling cassette PAC indoor unit with a nominal cooling capacity of 6.0 kW.

Technical Specifications


 

General Data
Nominal cooling capacity (min-max) kW 5.6 (1.1 – 6.3)
Nominal heating capacity (min-max) kW 6.7 (0.6 – 6.7)
Exterior Dimensions (H x W x D) mm Unit: 248 x 570 x 570; Panel: 35 x 700 x 700
Net Weight kg 18.5 (Unit: 15; Panel: 3.5)
Air Flow Cooling (Hi/Me/Lo) m3/min 13. 5/ 13.5 / 10 / 7
Air Flow Heating (Hi/Me/Lo) m3/min 13. 5/ 13.5 / 10 / 8
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 47 / 46 / 39 / 30
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 47 / 46 / 39 / 32

 

Schematics



Compact Ceiling cassette – Outdoor Unit

SRC60ZMX-S
PAC outdoor unit with a nominal cooling capacity of 6.0 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 5.6 (1.1 – 6.3)
Nominal heating capacity (min-max) kW 6.7 (0.6 – 6.7)
EER (Energy Label) 2.81
COP (Energy Label) 3.24
Exterior Dimensions (H x W x D) mm 640 x 800 (+71) x 290
Net Weight kg 45
Sound Pressure Level (Cooling/Heating) dB(A) 54/54
Energy class (Cooling/Heating) A+/A
SEER “Average climate”/(Energy label) 5.76
SCOP “Average climate”/(Energy label) 3.80

 

 

Electrical Data
Pdesignc kW 5.6
Pdesignh (@-10°C) kW 5.9
Annual electricity consumption (Cooling/Heating) kWh/a 341 / 2172
Power Source 1 Phase 220-240V 50Hz, 1 Phase 220V 60Hz
Inrush current (220/230/240v) A 5
Max. running current A 15
Power consumption (Cooling/Heating) kW 1.99 / 2.07

 

Installation
Refrigerant (GWP) R410A (2088)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 12.7 (1/2″)
Ref. Max Piping Length m Max. 30
Vertical Height differences / Outdoor is higher/lower m Max. 20 / Max. 20

Schematics


[:tr]

FDTC60VF

Compact Ceiling Cassette – Indoor Unit

FDTC60ZMXVF

Ceiling cassette PAC indoor unit with a nominal cooling capacity of 6.0 kW.

Technical Specifications


 

General Data
Nominal cooling capacity (min-max) kW 5.6 (1.1 – 6.3)
Nominal heating capacity (min-max) kW 6.7 (0.6 – 6.7)
Exterior Dimensions (H x W x D) mm Unit: 248 x 570 x 570; Panel: 35 x 700 x 700
Net Weight kg 18.5 (Unit: 15; Panel: 3.5)
Air Flow Cooling (Hi/Me/Lo) m3/min 13. 5/ 13.5 / 10 / 7
Air Flow Heating (Hi/Me/Lo) m3/min 13. 5/ 13.5 / 10 / 8
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 47 / 46 / 39 / 30
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 47 / 46 / 39 / 32

 

Schematics



Compact Ceiling cassette – Outdoor Unit

SRC60ZMX-S
PAC outdoor unit with a nominal cooling capacity of 6.0 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 5.6 (1.1 – 6.3)
Nominal heating capacity (min-max) kW 6.7 (0.6 – 6.7)
EER (Energy Label) 2.81
COP (Energy Label) 3.24
Exterior Dimensions (H x W x D) mm 640 x 800 (+71) x 290
Net Weight kg 45
Sound Pressure Level (Cooling/Heating) dB(A) 54/54
Energy class (Cooling/Heating) A+/A
SEER “Average climate”/(Energy label) 5.76
SCOP “Average climate”/(Energy label) 3.80

 

 

Electrical Data
Pdesignc kW 5.6
Pdesignh (@-10°C) kW 5.9
Annual electricity consumption (Cooling/Heating) kWh/a 341 / 2172
Power Source 1 Phase 220-240V 50Hz, 1 Phase 220V 60Hz
Inrush current (220/230/240v) A 5
Max. running current A 15
Power consumption (Cooling/Heating) kW 1.99 / 2.07

 

Installation
Refrigerant (GWP) R410A (2088)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 12.7 (1/2″)
Ref. Max Piping Length m Max. 30
Vertical Height differences / Outdoor is higher/lower m Max. 20 / Max. 20

Schematics


[:]