Description
FDE60VG x4
Ceiling Suspended – Indoor Unit
FDE250VSADVG
Ceiling suspended PAC indoor unit with a nominal cooling capacity of 6.0 kW.
Technical Specifications
Data Sheet (Printer Friendly)
Nominal cooling capacity (min-max) | kW | 25.0 (10.0 – 28.0) |
Nominal heating capacity (min-max) | kW | 28.0 (9.5 – 31.5) |
Exterior Dimensions (H x W x D) | mm | Unit:210 x 1320 x 690 |
Net Weight | kg | 33 |
Air Flow Cooling (Hi/Me/Lo) | m3/min | 20/ 16 / 13/ 10 |
Air Flow Heating (Hi/Me/Lo) | m3/min | 20/ 16 / 13/ 10 |
Sound Pressure Level Cooling (Hi/Me/Lo) | dB(A) | 47/ 41 / 37 / 32 |
Sound Pressure Level Heating (Hi/Me/Lo) | dB(A) | 47/ 41 / 37 / 32 |
Schematics
Ceiling Suspended – Outdoor Unit
FDC250VSA
PAC outdoor unit with a nominal cooling capacity of 25.0 kW.
Technical Specifications
Nominal cooling capacity (min-max) | kW | 24.0 ( 6.9-28.0 ) |
Nominal heating capacity (min-max) | kW | 27.0 ( 5.5 – 31.5 ) |
EER (Energy Label) | – | 3.00 |
COP (Energy Label) | – | 3.85 |
Exterior Dimensions (H x W x D) | mm | 1505 x 970 x 370 |
Net Weight | kg | 143 |
Sound Pressure Level (Cooling/Heating) | dB(A) | 59 /62 |
Power Source | – | 3 Phase 380-415V, 50Hz, 3 Phase 380V 60Hz |
Inrush current (220/230/240v) | A | 5 |
Max. running current | A | 21 |
Power consumption (Cooling/Heating) | kW | 8.00 / 7.02 |
Ref. Piping Size (Liquid/Gas) | Ø mm | 12.7 (1/2″) / 22.22 (7/8″) |
Ref. Max Piping Length | m | Max. 70 |
Vertical Height differences / Outdoor is higher/lower | m | Max. 30 / Max. 15 |