Single Splits – PAC Ceiling Cassette / FDT140VNVF

Категория:

Описание

FDT140VF

Cassette — Indoor Unit

FDT140VNVF

Ceiling cassette PAC indoor unit with a nominal cooling capacity of 14.0 kW.

Technical Specifications


 

General Data
Nominal cooling capacity (min-max) kW 14.0 (5.0 — 14.5)
Nominal heating capacity (min-max) kW 16.0 (4.0 — 16.5)
Exterior Dimensions (H x W x D) mm Unit: 298 x 840 x 840; Panel: 35 x 950 x 950
Net Weight kg 32.5 (Unit: 27; Panel: 5.5)
Air Flow Cooling (Hi/Me/Lo) m3/min 37/ 30 / 27 / 23
Air Flow Heating (Hi/Me/Lo) m3/min 37/ 30 / 27 / 23
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 51/ 43 / 41 / 38
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 51/ 43 / 41 / 38

 

Schematics



Ceiling cassette — Outdoor Unit

FDC140VN
PAC outdoor unit with a nominal cooling capacity of 14.0 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 14.0 (5.0 — 14.5)
Nominal heating capacity (min-max) kW 16.0 (4.0 — 16.5)
EER (Energy Label) 2.81
COP (Energy Label) 3.50
Exterior Dimensions (H x W x D) mm 845 x 970 x 370
Net Weight kg 81
Sound Pressure Level (Cooling/Heating) dB(A) 51/51

 

 

Electrical Data
Power Source 1 Phase 220-240V 50Hz, 1 Phase 220V 60Hz
Inrush current (220/230/240v) A 5
Max. running current A 24
Power consumption (Cooling/Heating) kW 4.98 / 4.57

 

Installation
Ref. Piping Size (Liquid/Gas) Ø mm 9.52 (3/8″) / 15.88 (5/8″)
Ref. Max Piping Length m Max. 50
Vertical Height differences / Outdoor is higher/lower m Max. 30 / Max. 15