Single Splits – PAC Ceiling Suspended / FDE71VNPVG

Category:

Description

FDE71VG

Ceiling Suspended – Indoor Unit

FDE71VNPVG

Ceiling suspended PAC indoor unit with a nominal cooling capacity of 7.1 kW.

Technical Specifications


Data Sheet (Printer Friendly)

 

General Data
Nominal cooling capacity (min-max) kW 7.1 (1.4 – 7.1)
Nominal heating capacity (min-max) kW 7.1 (1.0 – 7.1)
Exterior Dimensions (H x W x D) mm Unit:210 x 1320 x 690
Net Weight kg 33
Air Flow Cooling (Hi/Me/Lo) m3/min 20/ 16 / 13/ 10
Air Flow Heating (Hi/Me/Lo) m3/min 20/ 16 / 13/ 10
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 47/ 41 / 37 / 32
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 47/ 41 / 37 / 32

 

Schematics



Ceiling Suspended – Outdoor Unit

FDC71VNP

PAC outdoor unit with a nominal cooling capacity of 7.1 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 7.1 (1.4 – 7.1)
Nominal heating capacity (min-max) kW 7.1 (1.0 – 7.1)
EER (Energy Label) 2.84
COP (Energy Label) 3.62
Exterior Dimensions (H x W x D) mm 640 x 800(+71) x 290
Net Weight kg 45
Sound Pressure Level (Cooling/Heating) dB(A) 54/54
Energy class (Cooling/Heating) A++/A+
SEER “Average climate”/(Energy label) 6.35
SCOP “Average climate”/(Energy label) 4.22

 

 

Electrical Data
Pdesignc kW 7.1
Pdesignh (@-10°C) kW 5.8
Annual electricity consumption (Cooling/Heating) kWh/a 392/1925
Power Source 1 Phase 220-240V 50Hz, 1 Phase 220V 60Hz
Inrush current (220/230/240v) A 5
Max. running current A 14.5
Power consumption (Cooling/Heating) kW 2.50/ 1.96

 

Installation
Refrigerant (GWP) R410A (2088)
Designated heating season Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4″) / 12.7 (1/2″)
Ref. Max Piping Length m Max. 30
Vertical Height differences / Outdoor is higher/lower m Max. 20 / Max. 20

Schematics