Description
FDUM50VF x2
Low Static Pressure Duct Connected – Indoor Unit
FDUM100VSXPVF
Low static pressure duct connected PAC indoor unit with a nominal cooling capacity of 5.0 kW.
Technical Specifications
Nominal cooling capacity (min-max) | kW | 10.0 (4.0 – 11.2) |
Nominal heating capacity (min-max) | kW | 11.2 (2.5 – 16.0) |
Exterior Dimensions (H x W x D) | mm | Unit:280 x 750 x 635 |
Net Weight | kg | 29 |
Air Flow Cooling (Hi/Me/Lo) | m3/min | 13/ 10 / 9 / 8 |
Air Flow Heating (Hi/Me/Lo) | m3/min | 13/ 10 / 9 / 8 |
Sound Pressure Level Cooling (Hi/Me/Lo) | dB(A) | 37/ 32/ 29 / 26 |
Sound Pressure Level Heating (Hi/Me/Lo) | dB(A) | 37/ 32/ 29 / 26 |
Schematics
Low Static Pressure Duct Connected – Outdoor Unit
FDC100VSX
PAC outdoor unit with a nominal cooling capacity of 10.0 kW.
Technical Specifications
Nominal cooling capacity (min-max) | kW | 10.0 (4.0 – 11.2) |
Nominal heating capacity (min-max) | kW | 11.2 (2.5 – 16.0) |
EER (Energy Label) | – | 3.76 |
COP (Energy Label) | – | 3.71 |
Exterior Dimensions (H x W x D) | mm | 1300 x 970 x 370 |
Net Weight | kg | 105 |
Sound Pressure Level (Cooling/Heating) | dB(A) | 48/50 |
Energy class (Cooling/Heating) | — | A/A |
SEER “Average climate”/(Energy label) | — | 5.11 |
SCOP “Average climate”/(Energy label) | — | 3.87 |
Pdesignc | kW | 10.0 |
Pdesignh (@-10°C) | kW | 10.0 |
Annual electricity consumption (Cooling/Heating) | kWh/a | 685 / 3614 |
Power Source | – | 3 Phase 380-415V 50Hz, 3 Phase 380V 60Hz |
Inrush current (220/230/240v) | A | 5 |
Max. running current | A | 15 |
Power consumption (Cooling/Heating) | kW | 2.66 / 3.02 |
Refrigerant (GWP) | – | R410A (2088) |
Designated heating season | – | Average |
Ref. Piping Size (Liquid/Gas) | Ø mm | 9.52 (3/8″) / 15.88 (5/8″) |
Ref. Max Piping Length | m | Max. 100 |
Vertical Height differences / Outdoor is higher/lower | m | Max. 30 / Max. 15 |