Single Splits – RAC Wall Mounted / SRK60ZMX-S / SRC60ZMX-S

Category:

Description

SRK60ZMX-S

Wall Mounted – Indoor Unit

SRK60ZMX-S / SRC60ZMX-S

Wall-mounted RAC indoor unit with a nominal cooling capacity of 6.0 kW.

Technical Specifications


Data Sheet (Printer Friendly)

 

General Data
Nominal cooling capacity (min-max) kW 6.1 (1.1~6.8)
Nominal heating capacity (min-max) kW 6.8 (0.6~8.2)
Exterior Dimensions (H x W x D) mm Unit:309 x 890 x 220
Net Weight kg 13.5
Air Flow Cooling (Hi/Me/Lo) m3/min 14.5 / 12.5 / 8.5 / 7.0
Air Flow Heating (Hi/Me/Lo) m3/min 17.5 / 15.0 / 11.0 / 8.5
Sound Pressure Level Cooling (Hi/Me/Lo) dB(A) 51 /41 / 29 / 25
Sound Pressure Level Heating (Hi/Me/Lo) dB(A) 48 / 41 / 34 / 27


Schematics



Wall Mounted - Outdoor Unit

SRC60ZMX-S
RAC outdoor unit with a nominal cooling capacity of 6.0 kW.

Technical Specifications


 

 

General Data
Nominal cooling capacity (min-max) kW 5.0 (1.1~5.8)
Nominal heating capacity (min-max) kW 6.8 (0.6-8.2)
EER (Energy Label) - 3.26
COP (Energy Label) - 4.07
Exterior Dimensions (H x W x D) mm 640 x 800(+71) x 290
Net Weight kg 45
Sound Pressure Level (Cooling/Heating) dB(A) 54/54
Energy class (Cooling/Heating) -- A+/A+
SEER "Average climate"/(Energy label) -- 6.0
SCOP "Average climate"/(Energy label) -- 4.36

 

 

Electrical Data
Pdesignc kW 6.10
Pdesignh (@-10°C) kW 6.10
Annual electricity consumption (Cooling/Heating) kWh/a 356/1960
Power Source - 1Phase, 220 - 240V, 50Hz
Inrush current (220/230/240v) A 8.6 / 8.2 / 7.9
Max. running current A 15
Power consumption (Cooling/Heating) kW 1.87 / 1.67

 

Installation
Refrigerant (GWP) - R410A (2088)
Designated heating season - Average
Ref. Piping Size (Liquid/Gas) Ø mm 6.35 (1/4") / 12.7 (1/2")
Ref. Max Piping Length m Max. 30
Vertical Height differences / Outdoor is higher/lower m Max. 20 / Max. 20

Schematics